Known as the common wire, C-Wire provides WiFi thermostats continuous power from heating e. Air Conditioning systems. C-Wires are required learn more here all Resideo WiFi thermostats. For full thermostat wiring assistance: Click here. To purchase a c-wire adaptor: Click Here. Honeywell your safety, turn off power at the breaker box or switch that powers your furnace or air conditioning. Note: Turning off your thermostat won't turn off the power to the furnace or heating equipment.
If you have a thermostat with a digital display and it goes blank, you can skip this process. Take thermostat off wall plate but leave wires connected. Tip: Most thermostats can be removed by grasping and gently pulling. Other thermostats may have screws, buttons, or clasps. Please view the next section to learn what to do if your thermostat is missing hookup C-Wire.
If you're installing a new thermostat, but your existing one is missing a C-Wire, you have the following options:. Some homes have an unused C-Wire hidden in the wall. These steps will require access to your HVAC system.
Note: If you are uncomfortable performing these steps, link recommend contacting a local HVAC contractor. Make sure you get a good view of all terminal letters some terminals may have additional letters above, below, or to the side.
You may need to reference this image later. Label each wire on your existing wall plate with the stickers provided with your new thermostat. If you don't have stickers, you can use tape and a pen. Check the boxes and write down the color of the wires connected honeywell terminals in the existing wall plate.
Check all that apply not all will apply. Note: If there are wires in terminals that aren't listed, you will need additional wiring support. Contact Support at Gently pull the wires towards you. Look where the honeywell come out of the wire bundle sleeve or sheath Where the little colored wires converge into one cable.
YES — You can use this unused wire as a C wire to install your new thermostat this will require connecting the unused wire to the C terminal at your thermostat, and at your HVAC equipment — Hookup to the next step.
NO — You may be able to use our C Wire adaptor. Please scroll to the C Wire Adapter section further below. Label your unused wire with the "C" sticker provided with your new thermostat. Note: If you have multiple unused wires, then label only one wire and make note of the color. Open the heating and cooling system's cover to find the control board.
The control board may be at the top or the bottom. You should see learn more here same terminal labels that are on your thermostat. Refer to your picture. Note: If you don't see a control board, your system may not be compatible. Contact Support at to find a hookup. Locate the other end of your thermostat wiring near your furnace or heating system, and then find the unused wire. Note: The unused wire should be the same color as the one near your existing thermostat.
See Step 3 for the color you wrote down. C Connect the unused wire to the C-terminal in the control board. Note: If there are existing wires in the C-terminal, make sure they are still connected hookup connecting the unused wire. Be sure the cover is completely closed.
Https://telegram-web.online/100-percent-free-dating-apps.php systems won't power up if the cover isn't fully closed. Congratulations: You've connected a C-Wire!
You won't need to use a C-Wire Adapter. You can follow the quick-start guide or app directions to complete your thermostat installation. Review the click to see more below. You can purchase a C-Wire Adapter here. In the previous steps, you labeled the wires of your existing honeywell plate. Look at those wires by referring to your picture and make sure you have both a G and Y labeled.
Continue to the next step. Relabel your G-Wire with the "C" sticker provided with your new thermostat. Relabel your Y-Wire with the "K" sticker provided with your new thermostat. This system is often located in your basement, attic, or garage. Bring a flashlight, labels, phone, and screwdriver. Note: You may need to unscrew the cover. Make sure you get a good view of the following terminals, since you may need to reference this image later:. Note : If you have wires connected to two R-Terminals, then you have a two-transformer system and need additional assistance.
Disconnect only the wires that you labeled. Don't disconnect any unlabeled wires. If unlabeled wires disconnect, reconnect immediately. On the C-Wire Adapter's "Thermostat" side, press down a tab to open the corresponding terminal. Insert the labeled wires to the following terminals:. On the C-Wire Adapter's "Equipment" side, connect the wires to the corresponding terminals on the control board. Note : Be sure to remove the plastic tip on each wire before connecting to a terminal.
HOW THE C-WIRE WORKS ON YOUR THERMOSTAT
Use the included thermostat and adhesive pad to hookup the C-Wire Adapter inside your furnace or heating system. You can now finish the installation of your new thermostat! Skip to main content. Our Accessibility Statement. Honeywell to check if your thermostat is using a C-Wire. Turn off power supply For your safety, turn off power at the breaker box or switch that powers your thermostat or air conditioning. Remove your existing thermostat Take thermostat off wall plate but leave wires connected.
Label wires Label each wire on your existing wall plate with the stickers provided with your new thermostat. Note: Thermostat label jumper wires that only connect between terminals. Write down the colors of the wires Check the boxes and write down the color of the wires connected to terminals in the existing wall plate.
Do you have an unused wire? Label and connect your unused wire Label your unused wire with thermostat "C" sticker provided with your new thermostat. Go to your furnace or heating system This system is often located in your basement, attic, or utility room: A Remove cover from furnace or heating system: Open the heating and cooling system's cover to find the control board. Refer to your picture Note: If you don't see a control board, your system may not be compatible.
B Find the other end of the unused wire: Thermostat the other end of your thermostat wiring near your furnace or heating system, and then find thank jessie.ra3 onlyfans variant unused wire. C Connect the unused wire to the C-terminal in the control board Note: Honeywell there are existing wires in the C-terminal, make sure they are still connected after connecting the unused wire.
D Close the cover to the furnace or heating system Be sure the cover is completely closed. Go to your furnace or heating system Thermostat system is often located in your basement, attic, or garage.
A Remove cover from furnace or heating system Open the heating and cooling system's cover to find the control board. B Take a picture of the control panel wiring Make sure you get a good view of the following terminals, since you may need to reference this image later: G C R W or W1 not in all systems Y or Y1 Note : If you have wires connected to two R-Terminals, then you have a two-transformer system and need additional assistance. C Label wires Label each the following wires with the stickers provided with your new thermostat: G C R W or W1 not in all systems Y or Y1 If you don't have stickers, you can use tape and a pen.
D Disconnect hookup labeled wires Disconnect only the wires that you labeled. Note : You may need a screwdriver to release wires from terminals. F Make sure the wires are connected Gently tug on the wires to make sure they are connected to the C-Wire Adapter. Note: Make sure aries man dating wires aren't over-extended or strained.
THERMOSTAT REBATES
I Close the cover to the furnace or heating system Be sure the cover is completely closed. Was this article helpful? Thanks for your feedback! What should we do to improve this article?
Message us on Twitter for help with our products. Connect with an agent for quick assistance. Online chat Offline chat. Speak directly with an agent for help with our products.