Hook up electrical outlet

How to Wire 2 Outlets In One Box - Wiring a Double Receptacle the Correct Way

Instructions

According to African dating free, an outlet is the point outlet in an electrical wiring system where current can hook taken and utilize by electrical appliances and equipment by plugging electrical in it. An outlet receptacle where one or more receptacle are installed or a supply contact device installed at the outlet to connect an electrical load through plugs and switches. Ordinary outlet or standard outlet has screws terminals on both sides.

The brass screws should be connected to the line hot, live or phase wire while the silver screws should be connected to the Neutral wire. In other words, the hot wire from main breaker should be connected to the narrow blade terminal where the Neutral wire should be connected to the wide blade terminal. The ground wire is connected to the ground terminal mostly green color screw.

What You'll Need

Keep in mind that the brass screws for hot terminals are electrically bounded to each other by a break way fin tab hence, connecting one brass screw to hot wire will feed the power to the second brass screw as well. In some case, you may remove the breakaway fin tab between the two brass screws for hot wire and split the outlet for other specific application we will show in following wiring diagrams.

In today wiring tutorials, we will be showing that how to wire and install an electrical outlet in different ways. In this simple wiring diagram, multiple outlets have been connected in parallel. Each outlet is independent of each others as they are wired to separate cables. The following wiring diagrams show that multiple outlets are wired to a single pole SPST outlet, one-way or two way in US switch. In outlet wiring, a switch is added to to an existing outlet by removing the hot wire from outlet brass terminal and connected to the first terminal of switch.

The second terminal of switch then connected back to the brass terminal of outlet. In this wiring, a light switch has been added to the existing outlet. The hot terminal of outlet is connected to the first terminal of switch and the second terminal of switch is connected to the lighting point. Finally, the neutral wire from outlet is connected to the light bulb. In this wiring, the outlet operation has been split into two parts i.

To do this, simply remove the breakaway fin tab between the brass terminals hot as shown in fig. Connected the switch output hot to the upper brass terminal and the lower hot terminal should be connected to the switch input hot wire. In simple words, a common hot wire should be connected to hook first terminal of switch and lower hot terminal of outlet.

How to Install an Electrical Outlet Receptacle

The second terminal of switch as hot should be connected to the upper hot terminal of outlet. Finally, connect the neutral hook ground wire accordingly as shown in fig below. In this wiring, the first and 3rd outlet hot terminals are connected to the Line 2 Blue and the second and last outlets hot terminals are connected to the Line 1 Red.

The neutral is connected from the main breaker to all outlets neutral terminal. Ground wire is connected to the outlets as well as shown in the fig. This way, all the dual outlets are connected to the single line of V and can supply V to the appliances. In this special wiring, a dual outlet is connected to both V and V where the upper portion provides V and the lower outlet provides V supply voltage.

The special please click for source outlet I, I are used in these kind of wiring. To do this, connect Electrical 1 and Line 2 to the lower hot terminals respectively. Connect the neutral and ground to the brass outlet and ground terminal respectively. For example, hook a 15A air condition is connected to the upper V outlet and 10A, V heater to the lower terminal, the overall amperage is exceeding then than the switch rating.

Alternatively, you can plug W bulbs to the lower V outlet, no matter if the upper outlet of V, 15A is operational for air condition as the total amperage is not exceeding the 20A for specified outlet.

In this wiring, a 20A, V outlet is connected to the V supply through hot, neutral and ground wire. In this wiring, the line 1 and line 2 is connected to the brass terminals accordingly. No need of neutral is need in V. The ground wire is connected to the ground terminal. In this wiring, a 30A, V outlet is wired for dryer where the neutral is needed as well.

The Line 1, Line 2, Ground and Neutral wires are connected to the related electrical via 10 check this out 3 wires cable from separated breaker. For high loads and amperage, the Line 1, Line 2, Neutral and ground is connected through a 6 gauge 3 wires cable from separate breaker to the related terminals of hot 1, hot 2, neutral and ground terminal as shown in fig below.